M3T-B3 Relief HD Stereo Microscope

M3T-B3 Relief HD Stereo Microscope

 
M3T-B3 Relief HD Stereo Microscope

Service Microscope


M3T-B3 Relief HD Stereo Microscope 0.7-4.5X zoom power

                                 MRP Rs 15880


HD Trinocular Microscope Black Edition Full Metal
Relife RL-M3T-B3 (Base Size: 380×250)
Bringing you a new understanding and a magical world
HD Optical Objective, multilayer process
High Definition Coated Objective Lens, No Glare, Clear picture
Every small detail multi-layer precision manufacturing
Clear image, no vignetting
High transmittance, high refractive index
Metal mirror, standard eye silicone eye mask
All metal with FMC antireflection coating
High-eye-10x point wide-angle eyepiece
Lens diameter up to 25mm
0.5x CTV interface/0.7-4.5x continues zoom
360° rotating fixed rod
Suitable for PCB boards, electronic component, mobile phones repair etc.
What’s in the package:
Microscope Relife RL M3T-B3
1x HD Microscope Black Head
2x Eyepiece 10/20x
2x Silicone Eye Mask
1x CTV Digital Camera adapter 0.5x
1x Column complete with Microscope Head Support
1x Large support base (Size: 380 x 250)
1x Circular Soft Led Light
1x Auxiliary Lens 0.5x or 0.7x
Notice
1. Microscope ought to be placed in a dry and clean place. Do not expose the microscope in the sun directly. Avoid high temperature and violent vibration. 
2. As microscope is a precision instrument, handle with care, avoiding impact or abrupt movement during transportation.
 3. To keep the image clear, do not leave fingerprints or stains on the surfaces of the lens. 
4. Never turn the left and right Zoom control knob in the adverse direction at the same time, otherwise the microscope will be damaged. 
5. When removing the film from camera, use one hand to hold the camera so that it does not fall over.


Maintenance 
1. All lenses must be kent clean Fine dust on the surface of the lens should be blown off with hand blower or wiped off gently with a soft lens tissue; Fingerprints or oil marked on it should be wiped off with a tissue moistened with a small amount of xylene or a 3:7 mixture of alcohol and ether. 
2. Never use the organic solution to clean the other surface (especially the plastic surfaces). If necessary, please choose the neutral detergent.
 3. Do not take the microscope apart for fearing that it is damaged. 
4. After using, cover the microscope with the dust-cover provided and store it in a dry and clean place free from moisture to prevent rust.
 5. To keep the performance of the microscope, please check it periodically. The detail can be gotten from the agent nearby.

 Troubleshooting
 The performance of the microscope can't be made fully because of unfamiliar using, this table will give some advices. MADE(Remedy) OA( Trouble) E (Cause) Readjust it 
1. Interpupillary distance is not correct Readjust it Diopter adjustment is not correct Double images Magnification of each eyepiece is not the same size Mount the same size eyepiece 
2. Dirt on the specimen Clean the specimen Dirt appears in the field of view Dirt on the surfaces of eyepiece Clean the surface 
3. Dirt on the surfaces of the objectives Image is not clear Clean the objectives
4. Diopter adjustment is not correct Readjust the diopter Image is not clear while the focus changing Focus is not correct Readjust the focus 
5. The focusing knob is too tight The focusing knob is not smooth Loosen it to a suitable position 
6. The image is obscure because of the head slipping down by itself during observation tEi , A The focusing knob is too loose Loosen it to a suitable position 
7. Diopter adjustment is not correct Adjust the diopter Eyes fell tired easily Brightness of light is not correct Adjust the brightness 
8. The image on the monitor is not clear when the focusing knob is turned. Readjust the focus of video to a correct position The focus of video is not correct
 9. Use a wrong bulb Replace with a correct one Image brightness is not enough The voltage is too low Increase the input voltage ISO setting is too low Increase ISO or set to automatic


Configuration

RL-M3T 

Composition                                                                                Specification.         Quantity

E(Eyepiece 10x With Esd Capability, F.n. 20, Focusable)              Wh10X20.               2

XX EM (Microscope Body Only For Eyes)                                           7045                  1

E (Microscope Body For Eyes And C)                                              7045-TR.                1

CTV.                                                                                                       0.5.                     1

 AA Focusing Stage) EE (Stand With Esd Capability)                             A1.                  1

EH (Elastic Pressing Device)                                                                    E1                   1

TAIF (Black And White Reversible Stage Plate) g*                               SPBW              2

(Packing).                                                                                              1meter                1